Got Free Inquiry Now

We will contact you as soon as possible!

Efficient Air Outlet

Home /

Cleanroom Equipment

/

Efficient Air Outlet

/High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom

High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom

  • Lead Time:

    7-15
  • Product Orgin:

    China/Shandong
  • Shipping Port:

    Qingdao
  • Payment:

    T/T
  • Color:

    Static Spraying/304 Stainless Steel
Ensure superior air purity with our High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom applications. Featuring an integrated static pressure box, premium HEPA filter, and adaptable top or side duct connections, this unit delivers uniform airflow distribution while strictly meeting the highest hygiene and contamination control standards.

share it :

hot products

Contact us

Contact us

question?

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Contact us
  • Product Details

Engineered for mission-critical contamination control, our High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom delivers superior terminal air purification to meet stringent GMP and ISO standards. The integrated smooth diffuser plate ensures optimal, turbulence-free laminar airflow distribution, effectively preventing particulate buildup in aseptic processing environments. Constructed from premium powder-coated steel or stainless steel with airtight leak-free seals, this unit guarantees maximum biological safety. Alongside our cutting-edge hardware, we provide comprehensive cleanroom filtration services, including tailored engineering design, precision DOP/PAO testing port customization, and dedicated technical validation support to keep your pharmaceutical cleanroom running at peak performance.



The high-efficiency air outlet is an ideal terminal filtering device for the thousand-, ten-, and one-hundred-thousand-level purification air-conditioning systems, and can be widely used in clean air-conditioning systems in industries such as medicine, health, electronics, and chemical. The high-efficiency air outlet is used as a terminal filtering device for the transformation and construction of clean rooms of Class 1,000, Class 10,000, and Class 100,000, and is the key equipment to meet the requirements of cleanliness. The high-efficiency air outlet includes static pressure box, diffuser plate, high-efficiency filter, and the interface with the air pipe can be a top or side connection.


Features

1. The box body is welded with high quality cold rolled steel panel (electrostatic spraying) or stainless steel panel. Through special leakproof structure design and combined with special treatment of all welding lines, the possible leakage problem of the box body is avoided.

2. The fixation method of the diffuser panel is generally divided into side fixation and bottom fixation. Customers can choose according to their own requirements.

3. The filter stationary frame is made of the whole plate, which ensures the flatness of the filter fixed surface and effectively prevents air leakage.

4. Special filter press device can fix the filter well on the installation position, and it is easy to disassemble and install.

5. HEPABOX can be used for in-situ detection. Filter integrity test interface is reserved on the box, and PAO/DOP test can be conducted directly in the room.

6. HEPABOX can be used for in-situ inspection. The filter integrity test interface is reserved on the box, and PAO/DOP testing can be performed directly indoors.

7. Adjust valve and insulation layer can be installed according to user requirements.


HEPA Supply Unit


In order to ensure the filtration efficiency of the filter and the cleaning effect of the cleaning system, the high efficiency filter installation must comply with the requirements of clean room construction and acceptance code or design drawing.


1. Preparation before installation in order to prevent hepa from being polluted, the air cleaning system must be installed after the unpacking inspection and installation. The air conditioner, hepa box, air duct and clean room must be cleaned.Before installation, check the flatness of the end face of the filter frame or edge mouth, and the allowable deviation of the flatness of the end face should be no more than 1mm each.


If the flatness of the end surface exceeds the allowable deviation, only the frame end surface of the filter installation is allowed to be modified or adjusted, and the outer frame of the filter itself is not allowed to be modified, otherwise the filter material or sealing part in the filter will be damaged, reducing the filtering effect.


2. Installation requirements when installing hepa filters, ensure that the direction of airflow is consistent with the arrow mark on the outer frame.High efficiency filters assembled with corrugated plates must be vertically mounted, not in reverse.The high efficiency filter and the frame of the assembly high efficiency filter are usually sealed by the jacking method and the pressing method.

Graph of Initial Pressure Drop versus Face Velocity


Graph of Initial Pressure Drop versus Face Velocity


Air Inlet Collar and Damper Dimension


Air Inlet Collar Diameter (mm)

Air Inet Collar Standard Height (mm)

Damper Standard Height (mm)

¢ 250

60
230

¢ 300

60
280

¢ 350

60
330

¢ 400

60
430


Product Specifications


Filter Dimension

Casing Dimension

(Top Air Inlet)

Casing Dimension

(Side Air Inlet)

Air Flow

at 0.75m/s

Air Inlet

Collar Diameter

Rectangular Inlet 

Collar Dimension

Filter Initial 

Pressure Drop

L×W×H(mm)

L×W×H(mm)

L×W×H(mm)

(m3/h)

(mm)

(mm)

PAO H13(Pa)

PAO H14(Pa)

430×430×80 

500×500×280 

500×500×450 

500
250
200x200
180
205

430×430×100 

500×500×300 

500×500×450 

500
250
200x200
150
170

610×610×80

680×680×280 

680×680×450 

1000
300
300x200
180
205

610×610×100

680×680×300

680×680×450 

1000
300
300x200
150
170

915×610×80

985×680×280

985×680×450

1500
350
400x200
180
205

915×610×100 

985×680×300

985×680×450 

1500
350
400x200
150
170

1220×610×80

1290×680×280

1290×680×450

2000
350
500x200
180
205

1220×610×100

1290×680×300 

1290×680×450

2000
350
500x200
150
170

1220×915×80 

1290×985×280 

1290×985×450 

3000

Φ300*2 / Φ450*1

630x200
180
205

1220×915×100

1290×985×300

1290×985×450

3000
Φ300*2 / Φ450*1
630x200
150
170


Remarks:  

1. Side air outlet model only available with square port.

2. Dimensions above is suitable for mechanical-sealed and design with PAO testing port.

3. Tolerance of performance initial pressure drop is ± 10%.


Each type air filter in use after a period of time, due to capture the various filters filter material surface dust, so that the filtering efficiency of air filter and air filter resistance to drop, affects the central air conditioning unit or clean engineering supporting efficient delivery of air supply outlet, cleanliness and efficiency, the need to replace the air filter in time, to ensure that the air cleanliness requirements. 


All kinds of air filters and hepa filters are not allowed to tear or open the packaging bags or film by hand before installation.Air filters should be stored in strict accordance with the direction standards marked on the hepa packing case.In the process of hepa filter handling, should be handled, put, avoid violent vibration and collision.

Got Free Inquiry Now
We will contact you as soon as possible!
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Related Products

Laminar Air Flow Hood

Liquid Tank Sealed Laminar Flow Hood

The Liquid Tank Sealed Laminar Flow Hood is a premium air purification equipment providing a localized ultra-clean working environment. Equipped with advanced liquid seal technology, high-efficiency filters, reliable fans, and intuitive controls, this laminar flow hood effectively prevents particulate contamination to guarantee superior aseptic protection for critical laboratory and cleanroom operations.

At-will Combination, Unlimited Creativity.Different wave distance combinations and different rhythms.

84 Series Corrugated Steel Wall Panels At-Will Combination, Unlimited Creativity

Transform architectural facades with 84 Series Corrugated Steel Wall Panels. Featuring a dynamic combination of 84A, 84B, and 84C profiles with non-equal wave pitches, these corrugated steel wall panels eliminate monotonous lines with a distinctive visual rhythm. Enjoy at-will combination and unlimited creativity for striking, modern building aesthetics.

Electric Sliding Doors

Electric Sliding Steel Doors for Hospitals and Health Care Facilities

Engineered for superior hygiene, our electric sliding steel doors for hospitals and health care facilities are crafted from durable galvanized steel. Designed with antibacterial, anti-fouling, and moisture-resistant qualities, they provide exceptional thermal and sound insulation. These automated doors are easy to clean, ensuring a sterile, safe environment for medical facilities.

Coldroom Panel System

PIR/PU H-Type Cold Room Sandwich Wall Panel Manufacturers for with FM

As premier PIR/PU H-type cold room sandwich wall panel manufacturers with FM approval, we engineer superior thermal insulation solutions. Featuring premium PU/PIR cores and tight H-type joints, our cold room panels minimize heat transfer effectively. Available in widths of 930–1130mm and heights up to 26m, they ensure peak refrigeration efficiency.

Smart Cleanroom Doors

Security Smart Access Modular Cleanroom Doors For Pharmaceutical Clean Room With ISO9001

Enhance facility control with our Security Smart Access Modular Cleanroom Doors For Pharmaceutical Clean Room With ISO9001 certification. Designed for advanced access control and personnel monitoring, this integrated system utilizes a centralized module to streamline wiring and power distribution, delivering dependable safety, airtight sealing, and strict contamination control for critical environments.

Customized Cleanroom View Glass Panel

Customized Double-glazing Round Corner Cleanroom View Glass Panel

The Customized Double-glazing Round Corner Cleanroom View Glass Panel features durable hollow tempered glass flush with the door leaf for a seamless, aesthetic finish. Designed with elegant black or white printed borders, this premium cleanroom view panel prevents fogging caused by temperature and humidity fluctuations, ensuring optimal, unobstructed observation in sterile environments.

Elegant atmospheric m-wave curve;Hidden screw structure, beautiful and delicate

Concealed Fastener Ribbed Architectural Metal Siding Exterior Wall Cladding Panels

Enhance modern building aesthetics with our premium concealed fastener ribbed architectural metal siding exterior wall cladding panels. Featuring hidden screws and a sleek wave profile, these high-strength narrow panels deliver exceptional structural performance, modern appeal, and superior typhoon resistance for contemporary steel structures.

Cleanroom Ceiling Panel

Cleanroom Sandwich Ceiling Panel Installation Method (Cnsterilezoom Installation Technical Drawings)

Master the Cleanroom Sandwich Ceiling Panel Installation Method (Cnsterilezoom Installation Technical Drawings) to optimize your modular cleanroom construction. Designed for pharmaceutical, electronic, and food industries, these panels allow direct hole-cutting and reserved conduits to maximize installation efficiency while ensuring flush, aesthetic integration with cleanroom doors and windows.

 
Got Free Inquiry Now We will contact you as soon as possible!
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!